What can we help you with?
Keeping Pipe Organs Alive
- Providing technical services since 1999
- Manufacturer-independent assessment and recommendations
- Tuning, maintenance, repair, restoration, rebuilding and installation
- Expertise across pipework, wind systems, windchests, consoles and control systems
- A direct W-2 workforce for primary service, with third-party specialists used in collaboration with customers when unique projects require additional domain expertise
- In-house apprenticeship program for developing the next generation of pipe-organ technicians
- Written findings, work records and closeout documentation to support long-term continuity of instrument care
- Flat monthly billing programs offered for recurring tuning and maintenance
- National service coverage and long-term care relationships
Phone: +1 (888) 561-9121
Preserving Versus Replacing the Action
Whether the original action in a Wicks organ should be kept and serviced, repaired in part or replaced outright is decided by the particular instrument, and no published standard supports one treatment for every Wicks organ; the governing conservation principle, changing as much as necessary but as little as possible, is by its nature answered instrument by instrument, and the church guidance that frames restore-versus-replace sets no criteria for which instruments are poor candidates for restoration. Four things have to be established before that decision can be defended: whether the action is original Wicks work at all, what a documented examination shows about its condition and significance, which published standard the treatment is measured against, and whether the parts a repair would need still exist.
The documented Wicks projects below show what retention and replacement have actually involved on named instruments; each is one project and none is a rule. This page does not re-narrate the water and rodent cases, compare relay generations or explain the mechanism; those belong to Water and Rodent Damage in Direct-Electric Organs, to Wicks Control-System Generations and Relay Replacement Decisions and to Wicks DIRECT-ELECTRIC Action: Meaning, Boundaries, and Comparison respectively, and the company behind the nameplate is introduced at Wicks Organ Company.
Establish what the instrument is first
Is the action original Wicks work
A Wicks nameplate does not by itself establish that the instrument has direct-electric action: the company states that it built 275 instruments in its first thirteen years using pneumatic and mechanical actions, and as of August 31, 2026 its own parts page offers replacement parts for ‘tracker action, Tubular, Electro-Pneumatic, and DIRECT-ELECTRIC action instruments from 1914 to the present day’. Where a given instrument sits in that sequence is a dating question, and Identifying and Dating Wicks Organs, Companies, and Opus Suffixes owns it.
Nor are direct-electric chests proof that the action is original: the Pipe Organ Database record for Wicks Opus 67298 at First Methodist Church, Chicago Temple, states that Wicks ‘converted the chests to Direct Electric action’ during renovation work completed in May 1990, so direct-electric chests in a Wicks organ are neither evidence that they were built with the instrument nor a reliable basis for dating the action. That is one documented instrument, and it shows that such conversions happen rather than how often they do.
The practical consequence is that original action has to be established from the instrument and its records rather than assumed from the chest type, since a treatment chosen to preserve original Wicks work can otherwise end up preserving a later conversion. What factory paperwork is known to exist for a given instrument, and where it may be, is covered at Wicks Factory Records and Opus Documentation.
What an examination should record
An examination records the structure, materials, relevant history and condition of the instrument, including the extent and causes of deterioration, alteration and loss; that is how the Organ Historical Society’s Guidelines for Conservation and Restoration define the term, and the Guidelines do not prescribe a method for carrying it out. For the action decision each of those headings does work: structure and materials establish which chests carry the original valves and which, as at Chicago Temple, carry later ones; history establishes what earlier work was done and by whom; and condition establishes whether the deterioration affects one or two magnets or many, a distinction that matters because of the parts position described below.
The NSW Heritage Office and Organ Historical Trust of Australia guide lists the condition observations it expects an examination to include: wind leaks, cracks or splits, oxidation, insects, decay, water penetration, deterioration and wear.
The OHS Guidelines also separate examination from preventive conservation, which they define as all actions taken to slow deterioration by controlling the agents of decay, including environmental control, pest management and control of access, so an examination that records water penetration or rodent activity points to a preventive job as well as to a treatment decision. What is documented about water and rodent damage on named Wicks instruments, and what that evidence does not establish, is set out at Water and Rodent Damage in Direct-Electric Organs. Where removal of historic material proves unavoidable, the OHS 2008 guidelines require the affected components to be documented in their pre-restoration state first, so the examination record is also the baseline against which any later removal is justified.
Significance before treatment
Significance is assessed before any treatment is chosen: the NSW Heritage Office and Organ Historical Trust of Australia guide makes assessment of significance the first management step and has it guide the conservation and maintenance that follow. The same guide states that a significant organ should not be altered through enlargement or rebuilding because its significance may be compromised, a position conditioned on the instrument having first been assessed as significant. The Organ Historical Society’s guidelines add that historical design, materials or workmanship that fail a current restorer’s standards of quality still give authoritative testimony of past makers’ knowledge, skill and judgment, deserve respect as historical evidence, and should be retained wherever effort can achieve it.
For a Wicks organ the assessment therefore asks what this instrument documents, and an original DIRECT-ELECTRIC installation, an early pneumatic instrument and a later conversion document different things. Which era and type of Wicks work an instrument represents is a question for Wicks Organs by Tonal and Production Era and Wicks Unit Chests and Small-Organ Models, and the significance assessment draws on those answers and on the instrument’s own records.
The standard the decision is measured against
Minimum intervention and reversibility
A standard stated in the published guidance is minimum intervention: treatments ‘should change as much as necessary, but as little as possible’, in the words of the Organ Historical Society’s Guidelines, which also state that ‘whether literally possible or not, reversibility remains a useful, albeit idealized goal in all treatment’ and prefer additive treatments over subtractive ones. The same OHS guidance does not stop short of durability: the change should be enough for the instrument to function for a reasonable interval. Additive means adding to an incomplete component rather than replacing it entirely, and the Guidelines concede that reversibility may not be literally possible in a given case.
The 2008 guidelines further state that interventions should not modify the known aesthetic and physical characteristics of an organ, especially by removing or obscuring historic material, and that enlargements or modernizations should be strongly avoided whenever possible; the word is avoided, not prohibited, and the judgment rests with the project.
Reversibility is stated in similar terms elsewhere: as of August 31, 2026 the British Institute of Organ Studies says that ‘Any repairs or changes necessary during the course of restoration should be reversible, in case it be found at a later date that the work needs to be done again’, and the Association of Independent Organ Advisers, describing a typical conservation scope for a grant-funded project, specifies ‘No alterations, except to reverse changes’. The Organ Historical Society characterizes its 2008 Guidelines as seeking to ‘preserve historical evidence for future examination’ as well as to restore beauty and voice, which is why the examination record and the disposition of removed parts matter as much as the treatment itself.
Restoration, rebuilding and the words between them
Restoration and rebuilding are different pathways, and published guidance keeps them apart: the NSW Heritage Office and Organ Historical Trust of Australia guide defines repair, restoration, reconstruction, enlargement and rebuilding as distinct intervention pathways rather than interchangeable labels. The A. Thompson-Allen Company distinguishes restoration, appropriate when perishable materials fail, from rebuilding, which allows upgrades when an owner’s needs have changed, and notes that the reuse of old material somewhat limits the options available in a rebuild. The Archdiocese of New York’s 2017 guidelines use a simplified local terminology in which restoration returns an instrument to original condition without altering sound or action, while rebuilding retains the pipes on a new chassis; those are that document’s definitions, and conservation bodies use broader and sometimes different taxonomies.
Applied to a Wicks action, the distinction is between working on the original valves, magnets and wiring so that they continue to function and replacing the chest action or the switching with something new, and both appear in the documented Wicks projects below.
The Church of England’s ChurchCare guidance frames the choice around historic value and basic soundness: ‘If your organ is of historical value or is fundamentally sound, then the best advice is to restore it’, and ‘Destroying or substantially altering an historic instrument is poor stewardship and a loss to our cultural heritage’. A Diocese of Exeter advisory note contemplates the other outcome, that ‘In cases where the existing organ is in a poor state, it may be best to replace by a new or secondhand instrument’, and neither document sets out criteria for identifying an instrument that is a poor candidate for restoration.
When published guidance allows intervention
Published guidance also recognizes reasons to intervene, each within its own scope, and they are separate positions rather than a consensus with the conservation standard. The American Theatre Organ Society treats modern modifications as permissible where necessary for contemporary function, naming solid-state relay systems and combination actions as examples; its scope is theatre organs, where console mobility is a performance requirement that a fixed church instrument does not have.
The American Institute of Organbuilders states that retaining electrical equipment in older organs that does not meet current code standards is not recommended for reasons of reliability, safety and potential product liability, a criterion that can force a control-system replacement regardless of historic value; it is advisory and does not distinguish a historically significant switching system from ordinary wiring. John Bishop, writing in The Diapason, frames the governing tension as retaining an organ’s musical and artistic qualities while keeping in mind that the future of the pipe organ depends on an appropriate balance between artistry and expense, an opinion column that declines to make cost subordinate to conservation principle.
For a Wicks owner the practical reading is that the conservation standard governs how much is changed and how, while code, function and cost are the reasons a proposal will give for changing more, and a defensible decision names which standard it is applying and why.
What retention has looked like
Two projects on the builder’s own project list kept the original DIRECT-ELECTRIC action and worked on it, and each is evidence that retention is a real option on a particular instrument rather than a statement of what any other Wicks organ needs.
Rewiring and lubricating an existing action
On Wicks Opus 2575 of 1944, in work the company reports as completed in April 2023, the original DIRECT-ELECTRIC magnets were kept: the report states that all the chests were rewired and all the magnets lubricated, while a new Syndyne relay system, new console and chamber rectifiers, a rebuilt console with new keyboards, added combination pistons and a new tablet board, and new actions on the 16-foot pedal offset chests were installed alongside them. The same project description includes releathering. The chest magnets were retained while the switching, the rectifiers and the console were renewed around them and the pedal offset chests received new actions, so retention and replacement sat side by side in one project. What a relay change adds and removes on a Wicks organ is the subject of Wicks Control-System Generations and Relay Replacement Decisions.
Adjustment on an instrument kept in service
On Wicks Opus 557 at the Basilica of Saint Louis, the Old Cathedral, the company’s project list records, as of September 1, 2026, installation of Tracker Touch on the existing manual keyboards and adjustment and lubrication of the DIRECT-ELECTRIC actions. That is one listed project; it records what was done and does not establish any relay, switching, console-control or combination-action work that the list does not mention. Neither project is offered as what a Wicks action needs or as a description of how the work is done; each shows that keeping the original action and servicing it has been a documented choice on a named instrument.
What the action is made of
A claim in the company’s glossary about DIRECT-ELECTRIC action is that it eliminates periodic releathering, and it has to be read precisely: the company’s glossary states that the system ‘eliminates both the periodic releathering required by the electro-pneumatic system, and the limitations of the mechanical connections of the tracker system’, which is a claim about the chest action and not a claim that a Wicks organ contains no leather, as the releathering in the company’s own Opus 2575 project description shows. The patented valve itself carries leather and felt: in both the 1922 and the 1929 Wick valve patents the pipe valve is a laminated disk made of a lower sole-leather disk, a middle soft-felt disk and an upper soft-leather disk, even though the design dispenses with a pneumatic motor.
The difference from electro-pneumatic action is one of transmission path: direct electro-mechanical action sends an electrical command to an electrical valve, whereas electro-pneumatic action combines the electrical command with pneumatic valve stages, and that distinction carries no claim about durability or failure rate. The mechanism itself, and how it compares with the actions beside it, is explained at Wicks DIRECT-ELECTRIC Action: Meaning, Boundaries, and Comparison. For the preservation question the point is that an original Wicks action has facing material that can perish and contacts that need periodic maintenance like any other electric action, so preserving it means keeping and maintaining a mechanism that deteriorates, not leaving alone one that cannot.
How electromechanical actions tend to fail
Colin Pykett’s characterization is that electromechanical organ actions usually fail gracefully rather than catastrophically, that cleaning an individual contact is often sufficient, and that they are the most robust action type against lightning strikes, while an instrument with hundreds or thousands of contacts requires periodic maintenance. That is one practitioner’s general observation, not a measured failure-rate study and not specific to Wicks; it addresses contacts and lightning rather than water, rodents or corrosion, and it is not an instruction to clean anything. Its value for the decision is that graceful failure is the pattern in which retention with ordinary maintenance remains possible, whereas the one documented Wicks project in which the original action was replaced wholesale followed rodent and water damage rather than gradual wear.
What replacement has looked like
Replacement has taken three documented forms on Wicks instruments: new valves throughout a chest action after damage, a division changed to another builder’s system during an enlargement, and a control system replaced while the chest action stayed; these are documented projects on named instruments, not a rule for any other.
Wholesale valve replacement after damage
On Wicks Opus 1500 of 1936, a Fuga-Deluxe self-contained instrument, the company reports rodent-caused cable failure and water damage from a leaking pipe that produced rust affecting the action, and describes ‘wholesale replacement of the original 1936 action, with 219 new electric action valves’, together with replacement of all gasketing material on the chest shell, rack and toe boards and of all the tuning slides, in work completed in July 2023. That project is the documented picture of the far end of the range: the original action was not retained, and the report ties that outcome to damage that reached the action itself.
In two of three named Wicks water-damage cases the remedy was whole-chest intervention rather than component repair: at Chicago Temple the renovation converted the chests to Direct Electric action, and at Morningside Presbyterian the instrument underwent complete rebuilding and modernizing including a new console. Neither source states that whole-chest work was technically necessary rather than chosen for other reasons, and no cost or condition threshold is given. What the water and rodent evidence documents, and what it does not establish about direct-electric action in general, is the subject of Water and Rodent Damage in Direct-Electric Organs.
Changing a division to another system
Original Wicks direct-electric chest action has also been removed in the course of an enlargement: a Rose City Organ Builders project narrative for a 1957 Wicks at First United Methodist Church, Portland, Oregon states that in the 2007 rebuild the ‘Solo division windchests were changed from direct electric action to rebuilt Wurlitzer systems’, as part of an enlargement to 107 ranks that also replaced the console and relay. In the vocabulary above that project is rebuilding, and it is the kind of enlargement the OHS 2008 guidelines say should be strongly avoided whenever possible and the Australian guide says should not be done to an organ assessed as significant; whether either standard applied to that instrument depends on a significance assessment of that instrument.
Replacing the control system rather than the action
A control-system replacement is a separate decision from a chest-action replacement, and it is documented on several Wicks instruments. As of September 1, 2026, the company’s project list records that the control system of Wicks Opus 4410 at Hope Lutheran Church, Highland, Illinois was replaced by Walker Technical Company, with the work recorded as completed in September 2023. Third-party control systems are documented on others: a 1975 Wicks, Opus 5523, received a new solid state relay and combination action in 2012; Opus 2575 received its Syndyne relay in the 2023 work described above; and the 1957 Portland instrument received a solid state relay by K & S Electronics in 1983 and a Uniflex computerized relay in the 2007 rebuild.
On Opus 2575 the relay was replaced and the chest magnets were kept, which is the clearest documented instance of the two decisions being made separately on one Wicks organ. Which generation of switching a given Wicks organ carries, what has been fitted to Wicks instruments and by whom, and what a conversion adds and removes are the subject of Wicks Control-System Generations and Relay Replacement Decisions.
Parts, and why they change the answer
Magnet production has not resumed
As of September 1, 2026, Wicks Organ LLC, which publishes the Wicks parts pages, states that it has not resumed production of its DIRECT-ELECTRIC action magnets, that it holds only a limited number of completed magnets plus magnet cores and assorted repair parts for service work, that it cannot accommodate volume purchases, and that no decision has been made on when production will resume. The parts page itself, as it stood on August 31, 2026, offers an Action Magnets category described as a limited number of completed magnets available for service work together with magnet cores, and states that production has not resumed, so magnet supply is presented as remaining stock rather than as current manufacture.
The company’s other replacement parts are described, as of the same date, as new old stock or previously enjoyed equipment for tracker, tubular, electro-pneumatic and DIRECT-ELECTRIC instruments ‘from 1914 to the present day’, and as ‘a limited selection of heritage repair parts available to owners of instruments of advanced experience’, supplied on inquiry rather than from a published catalog.
These are the company’s statements about its own stock on undated pages; they do not say whether third-party suppliers can furnish equivalent magnets or whether rewinding services exist, and they are not a guarantee that any particular part will be available when it is asked for.
One failed magnet against many
A fault affecting one or two magnets and an event that damages many magnets at once are materially different supply problems, because the company holds magnet cores and repair parts but not production quantities of completed magnets. That is a consequence of the stated stock position, not a claim that magnets fail in bulk after any particular hazard. It bears directly on the treatment decision: a repair that keeps the original action depends on a small number of parts being obtainable, so the examination should record how many magnets and valves are affected before anyone assumes that retention is or is not feasible.
A currently supplied direct-pallet magnet from another maker still seals with felt and leather: as of September 2, 2026 the Organ Supply Industries brochure for Reisner electromagnets specifies its 601 Direct Pallet Magnet with ‘soft felt and leather valves cemented to an aluminum valve carrier’. That is a supply-house component, not a Wicks factory part and not evidence about any particular historic instrument; it shows only that a direct-acting valve of that kind is still made with the same class of facing material. Key contacts, rectifiers and wiring are a separate supply and condition question, covered at Key Contacts, Rectifiers and Wiring in Wicks Organs.
Keeping options open
What counts as a major alteration
Replacement of the stop actions, combination action or relay system is classed as a major alteration rather than ordinary repair in the American Theatre Organ Society’s restoration guidelines, which the society describes as based on Organ Historical Society guidelines; where solid-state combination actions or relay systems are necessary to meet an installation’s requirements, those guidelines provide that the devices must be designed and installed to equal the aesthetic appearance, feel and functionality of the original console controls.
Published treatments of an original combination action or relay in a historic instrument differ, and they are separate positions rather than a consensus. The American Theatre Organ Society position is conditional permission classed as a major alteration, while the Organ Historical Society’s guidelines ask that every effort be made to retain historical work even where it fails current standards.
Two named instruments show what the range has looked like in practice. At Woolsey Hall, Yale University, the 1928 remote-control combination action of Skinner Organ Company Opus 722 was retained and remains usable while a solid-state combination action was piggy-backed onto the console. At St Peter’s Episcopal Church, Morristown, New Jersey, the parish states, as of September 1, 2026, that a new console will be built and the original 1930 console preserved, relocated for display and kept playable.
In 1998 Joseph Dzeda of the A. Thompson-Allen Company, objecting with the Curtis Organ Restoration Society to a University of Pennsylvania plan for an electronic console at Irvine Auditorium in place of restoring the original 1926 console, warned that electronic consoles depend on a technology which is not readily reproducible and are replaced wholesale the first time they encounter trouble; that report cannot establish what was eventually done.
Those are theatre-organ guidance and examples from other builders’ instruments, not Wicks projects; what they establish for a Wicks owner is that the published range runs from retention alongside new equipment to replacement with the original kept on display, and that the ATOS classification is the one that names the relay explicitly.
Disconnecting rather than removing
Where modernization is necessary, the ATOS guidelines advise disconnecting historic devices rather than removing them, so that the original equipment remains in place, and the same guidelines contemplate that original equipment such as setter boards may be left installed for historic purposes while being carefully disconnected for practicality. This is general 1992 guidance, and physical space inside a given console or chest may make retention impractical. For a Wicks organ the treatment applies most naturally to the switching layer, which the Opus 2575 project shows being replaced while the chest magnets stayed in place, and the OHS preference for additive over subtractive treatment points the same way.
Labeling and storing what comes out
Original parts that are removed or modified should be carefully packed, stored in a safe part of the building and properly labeled as to their significance, in the American Theatre Organ Society’s guidelines, and the Organ Historical Society’s 2008 guidelines say components and fragments that must be removed should be labeled and given archival storage whenever possible, so that historic evidence is preserved. On a Wicks project that means replaced valves, a changed chest or a superseded relay remain evidence of the original work, and a proposal that provides for their labeling and storage preserves that evidence for a later examination whatever treatment is chosen.
Scoping the work once the evidence is in
Routine service and comprehensive work
John Bishop, writing in The Diapason on July 14, 2025, draws a competence boundary between routine service and comprehensive work: ‘A local service technician might be well able to replace a pouch or two’ but lacks the skills and precision or the facility needed for comprehensive releathering, and he advises a church to assess a prospective contractor by ‘visiting a workshop known for high-quality leather work’. That is one practitioner’s advice to churches planning work, written about electro-pneumatic pouch and primary chests, and it is not a statement about any named firm. The shape of the boundary is what transfers: an examination that shows a few affected valves and one that shows a division affected describe work of different kinds, and the parts position above decides whether the first can be done from remaining stock.
Wicks Organ LLC lists, as of September 1, 2026, new chests and actions, solid state switching, consoles and keyboards among its rebuild offerings; that is a stated service list, not evidence of capacity, lead time, price or willingness to take on a particular instrument.
What a proposal should be able to point to
A treatment proposal for an original Wicks action can be tested against a documented record: a finding on whether the action is original, an examination under the OHS headings of structure, materials, history and condition, a significance assessment made before the treatment was chosen, the standard the treatment is measured against and the reasons for any departure from it, the number of magnets and valves affected set against the stated parts position, and the intended disposition of everything removed. Inspection and documentation of that kind precede any proposal, and the written record of what was found is what an owner, a committee or a later examiner can hold a treatment to, which is the sense in which the OHS Guidelines ask that historical evidence be preserved for future examination.
Frequently Asked Questions
It depends on the instrument, and no published source supports one treatment for every Wicks organ: the decision rests on establishing first whether the action is original Wicks work, then on a documented examination of the instrument’s structure, materials, history and condition as the Organ Historical Society defines examination, measured against the OHS principle of changing as much as necessary but as little as possible with reversibility as an idealized goal, and on whether the parts a repair would need still exist.
Only from remaining stock, on the company’s own account: as of September 1, 2026, Wicks Organ LLC states that production of its DIRECT-ELECTRIC action magnets has not resumed, that it holds a limited number of completed magnets plus magnet cores and assorted repair parts for service work, that it cannot accommodate volume purchases, and that no decision has been made on resuming production; this is the company’s dated statement about its stock, not a guarantee of supply.
Yes, in the American Theatre Organ Society’s restoration guidelines, which the society describes as based on Organ Historical Society guidelines: replacement of the stop actions, combination action or relay system is classed as a major alteration rather than ordinary repair, and the same guidelines advise disconnecting rather than removing historic devices where modernization is necessary, so that the original equipment stays in place.
An examination record and a plan for removed material: the Organ Historical Society defines examination as investigation of the structure, materials, relevant history and condition of the organ, including the extent and causes of deterioration, alteration and loss; its 2008 guidelines say components that must be removed should be labeled and given archival storage wherever possible; and the American Theatre Organ Society advises that removed or modified original parts be packed, stored safely in the building and labeled as to their significance; these are published conservation guidelines, not a specification for any particular project.
No: the Pipe Organ Database record for Wicks Opus 67298 at First Methodist Church, Chicago Temple, states that Wicks converted the chests to Direct Electric action in renovation work completed in May 1990, so direct-electric chests in a Wicks organ are not proof that the action is original and not a reliable basis for dating it; that is one documented instrument, which shows that such conversions occur rather than how common they are.